Spacecraft Sub Systems
Xenon Flow Controller (XFC)
Specifications
-
Operating Media
Xenon
-
Test Media
Helium, Argon and Nitrogen
-
Inlet Pressure
37 ±3 psia (2.55 ±.2 bar)
-
Operating Pressure (MEOP)
2700 psia (186 bar)
-
Proof Pressure
4050 psia (279 bar)
-
Burst Pressure
6750 psia (465 bar)
-
Flow Rate Range
6 to 20 mg/sec Xenon
-
Operating Temperature Range
68°F to 160°F (20°C to 50°C)
-
Non-Operating Temperature Range
-29°F to 160°F (–34°C to 71°C)
-
External Leakage
< 1x10-6 sccs Helium at MEOP
-
Internal Leakage per Valve
< 1x10-3 sccs Helium at MEOP
-
Mass
< 1.17lb (.53kg)
-
Overall Size
7.2 in x 5.4 in x 2.0 in (18.3 cm x 13.7 cm x 5.1 cm)