Pilot-Operated Servovalves for Analog Signals D791 and D792 Series

 

  • 3-stage valve design for high dynamics
  • Electrical position feedback (LVDT) - No wear
  • Integrated electronics with inverse polarity protection
  • Optional external pilot supply and return connections via additional x and y port in valve body
  • Low threshold and hysteresis, excellent stability at null
Specifications
Hydraulic Data  
Rated Flow 100 to 1,000 l/min (26.4 to 264 gpm) @ ∆p 35 bar (500 psi) per land
Maximum Flow 1,100 l/min (290 gpm) (D792)
Maximum Operating Pressure 350 bar (5,000 psi)
Mounting Pattern Moog Standard
100% Step Response 3 to 12 ms @ 210 bar (3,000 psi)
   
Electrical Data  
Supply Voltage +/- 15 VDC, 24 VDC (18 to 32 VDC)
Rated Signal Options +/-10 V, +/-10 mA and 4-20 mA
Options N/A